Vertiv's Advanced Liquid Cooling Solutions for Modern Data Centers

Revolutionizing thermal management with cutting-edge liquid cooling technology for high-density computing environments

Request a Consultation Request a Consultation

How Vertiv Liquid Cooling Works

Our advanced liquid cooling systems use thermodynamic principles to efficiently manage heat in high-density data center environments.

1

Heat Absorption

A pump circulates dielectric coolant through precision-engineered cold plates attached directly to heat-generating components like CPUs and GPUs, absorbing thermal energy through conduction.

2

Heat Transfer

The heated coolant is transported through insulated tubing to heat exchangers, efficiently moving thermal energy from servers to the cooling infrastructure.

3

Heat Dissipation

At the heat exchanger, thermal energy is transferred from the liquid coolant to the facility's chilled water system or directly to the atmosphere through dry coolers.

4

Cycle Continuation

The cooled dielectric fluid returns to the servers, creating a continuous closed-loop system that maintains optimal operating temperatures 24/7.

Benefits of Vertiv Liquid Cooling Technology

Discover how our liquid cooling solutions transform data center performance, efficiency, and sustainability.

Energy Efficiency

Reduce cooling energy consumption by up to 95% compared to traditional air cooling systems, significantly lowering operational costs.

Quieter Operation

Eliminate noisy server fans with our liquid cooling systems, creating a more pleasant working environment for data center staff.

Higher Density Computing

Support power densities exceeding 100kW per rack, enabling deployment of next-generation AI, HPC, and cloud computing workloads.

Sustainability

Achieve PUE values as low as 1.05 and reduce carbon footprint with our energy-efficient, closed-loop cooling systems.

The Evolution of Data Center Cooling

As computing power continues to increase, traditional air cooling methods are reaching their limits. With server rack densities now exceeding 30kW per cabinet, data center operators require more efficient thermal management solutions. Vertiv's liquid cooling technology represents the next generation of data center infrastructure, offering up to 4,000 times greater heat transfer efficiency than air-based systems.

Key Benefits of Vertiv Liquid Cooling

  • Up to 95% reduction in cooling energy consumption
  • Support for high-density computing up to 100kW per rack
  • Significant reduction in data center footprint
  • Enhanced server performance and reliability
  • Lower total cost of ownership (TCO)
  • Improved sustainability metrics (PUE)

Vertiv's Liquid Cooling Technology Portfolio

Direct-to-Chip Cooling

Vertiv's precision cooling solutions target heat at the source, with cold plates directly attached to CPUs, GPUs, and other high-heat components. This approach captures up to 80% of server heat, allowing for efficient heat rejection and enabling higher computational densities.

Immersion Cooling

For extreme density applications, Vertiv offers single-phase and two-phase immersion cooling solutions. Servers are submerged in dielectric fluids that absorb heat directly from all components, enabling unprecedented power densities while maintaining optimal operating temperatures.

Rear Door Heat Exchangers

Vertiv's rear door heat exchangers provide an efficient retrofit solution for existing data centers. These systems capture heat as it exits the server rack, transferring it to a liquid coolant without requiring modifications to the IT equipment itself.

Real-World Applications and Success Stories

"After implementing Vertiv's liquid cooling solution in our high-performance computing facility, we achieved a 40% reduction in energy costs while doubling our computational capacity. The reliability and performance have exceeded our expectations."

— Data Center Manager, Fortune 500 Financial Institution

"The transition to Vertiv's immersion cooling technology allowed us to deploy AI workloads at densities previously thought impossible. We've reduced our cooling infrastructure footprint by 70% while improving system reliability."

— CTO, Leading AI Research Laboratory

"Vertiv's direct-to-chip cooling solution enabled us to retrofit our existing data center for next-generation servers without expanding our facility. The project paid for itself in energy savings within 18 months."

— IT Director, Global Cloud Service Provider

Environmental Impact and Sustainability Benefits

Vertiv's liquid cooling solutions contribute significantly to environmental sustainability in data center operations. By dramatically reducing energy consumption for cooling, these systems help data centers achieve lower Power Usage Effectiveness (PUE) ratings, often approaching 1.05 compared to the industry average of 1.5-1.8 for air-cooled facilities.

The heat captured by Vertiv's liquid cooling systems can also be repurposed for building heating, district heating networks, or industrial processes, creating opportunities for energy reuse and further improving the environmental footprint of data center operations.

Environmental Impact

  • Carbon Reduction: Up to 80% lower CO2 emissions
  • Water Usage: Closed-loop systems minimize water consumption
  • Energy Reuse: Up to 70% of captured heat can be repurposed
  • PUE Improvement: Reduction from 1.6 to 1.1 on average

Implementation and Deployment Considerations

Assessment and Planning

Begin with a comprehensive assessment of your current data center infrastructure, including power density, cooling capacity, and future growth requirements. Vertiv's engineering team can perform a detailed site survey to determine the optimal liquid cooling solution for your specific needs.

Solution Design

Based on the assessment, Vertiv will create a customized design that integrates seamlessly with your existing infrastructure. This includes specifying the appropriate cooling technology, piping layout, pump requirements, and heat rejection systems.

Installation and Commissioning

Vertiv's certified technicians will install the liquid cooling system with minimal disruption to your operations. The commissioning process includes thorough testing and optimization to ensure peak performance and reliability.

Monitoring and Maintenance

Vertiv provides comprehensive monitoring solutions that track system performance in real-time. Regular maintenance ensures long-term reliability and optimal efficiency of your liquid cooling infrastructure.